What does a bathroom extractor fan cost in Devon?
Our guide range in Devon is £255–£600 including VAT.
Extractor fan
- Wired to regulations
Inline fan
- Quiet fan in the loft void
Continuous extract
- Boost on humidity
Guide prices for Devon including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Devon?
Most of Devon is supplied with soft water. Even so, condensation is the bigger problem in any bathroom, and a properly sized extractor is what deals with it. Hardness varies street by street, so check the figure for your postcode with your water supplier. If your Plymouth bathroom has black mould on the ceiling or silicone, the fan and its duct are the first things we check.
What the job includes
- Run-on timer, humidistat or light-linked switching set up to suit how the room is used
- Making good around the fan and checking that it extracts properly at the grille
- Core-drilling through the wall, or ducting through the loft to a roof or soffit vent
- Rigid or semi-rigid ducting kept short and straight, and insulated where it crosses a cold loft
- A backdraught shutter and external grille, so cold air does not blow back in
- A fan chosen to meet the bathroom extract rate: 15 l/s intermittent or 8 l/s continuous
Decisions to make first
Axial, centrifugal or inline
Axial fans suit short, straight runs; centrifugal fans cope better with longer ducts; inline fans sit in the loft and are the quietest in the room.
Noise
Compare the stated noise level in decibels. Inline fans and low-speed continuous fans are much quieter in the room than budget axial fans.
Replacement air
A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.
Timer or humidistat
A timer keeps the fan running after the light goes off. A humidistat starts it whenever moisture rises, which suits rooms where people forget.
Rules that apply in England
A bathroom needs extract ventilation when it is newly formed, and on a refit an existing fan should not be replaced with a less effective one. The fan and its wiring must meet BS 7671 for the zone it sits in, on a circuit with 30 mA RCD protection. In a flat, the lease often requires freeholder consent for a new extract vent, and in a listed building a new opening through an external wall can need listed building consent.
In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.