Free home survey & written quote · Fitted bathrooms across England, Wales, Scotland & Northern Ireland0800 088 6341
Fitted Bathrooms
Bathrooms & en-suites

Loft bathrooms and shower rooms under the eaves

A loft bathroom is a bathroom or shower room in the roof space of a house, usually in a loft conversion, with at least part of the ceiling sloping. Its layout is decided by headroom, and its water supply and waste have further to travel than anywhere else in the house.

From £5,500 inc VAT6–12 working daysFree home survey
Loft shower room under a sloping ceiling with a roof window

A bathroom in the loft is mostly a problem of height. You need standing room in the shower, at the basin and in front of the WC, but the roof slopes away from the ridge, so the layout follows the headroom rather than where the fittings would look nicest. A bath can sit under the slope as long as you can stand where you climb in; a shower needs full height over the whole tray.

The plumbing is the other half. If your hot water comes from a cylinder fed by a cold tank in the loft, there is very little pressure up there, so the shower may need a pump or the supply may need rethinking. The waste has to fall all the way to the soil stack. We check both at the survey, along with the floor joists, before quoting. Loft bathrooms typically cost £6,500 to £13,000 supplied and fitted, including VAT.

What does a loft bathroom with us include?

  • A survey of the headroom across the room, with the usable height marked at each fitting position
  • A check of your hot-water system and of the pressure and flow you actually get at loft level
  • A drainage route from the loft to the soil stack with enough fall, or a pumped waste or macerator where the rules allow it
  • A check of the floor joists where a bath or large shower tray will sit
  • A shower pump on a gravity system, an electric shower, or advice on moving to mains pressure, depending on your system
  • Fitted furniture made to the eaves, so the low space behind the slope becomes storage
  • An extractor fan ducted through the roof or a gable wall, with the duct insulated through cold spaces
  • Electrics by a qualified electrician, tested and certified, then tiling, testing and handover

How much does a loft bathroom cost?

Our UK guide range is £6,500–£13,000 including VAT. Typical prices by kind of job:

Refit

£5,500–£8,500
  • Existing loft shower room
  • Shower, basin and WC replaced
  • Tiling, lighting, extractor fan

New loft bathroom

£10,000–£18,000
  • Formed in an existing loft room
  • New drainage route and water supply
  • Ventilation and electrics to regulations

National guide prices including VAT, reviewed October 2026. London is typically about 25% higher and the North East, Wales and Northern Ireland around 7–12% lower. Your written quote after the survey is the price that counts.

What do you need to decide?

Where the shower goes

Under the ridge or in a dormer, where the full height is. A walk-in shower with a single panel is usually easier to fit to a roof line than a framed enclosure.

Bath or no bath

A bath under the slope makes good use of low space, but the floor has to carry it when it is full of water and someone is in it.

Getting the water pressure

A pumped shower suits a gravity system with a cold tank; an electric shower heats cold mains water at the point of use; a combi or unvented cylinder gives mains pressure throughout.

Roof window

A roof window over the bath or shower brings daylight and fresh air, but plan the blind for privacy and expect condensation on cold glass.

Gravity or pumped waste

Gravity is silent and maintenance-free. A pumped waste or macerator lets fittings sit away from the stack, provided the house has a WC on gravity drainage elsewhere.

Eaves storage

Low cupboards built into the slope behind the WC or basin take clutter out of the room and hide the pipework.

How does the job run?

  1. Headroom and structure

    We map the headroom, look at the joists and roof structure, and note where the soil stack and water tank sit.

  2. Water and waste plan

    We work out how the shower will get its pressure and how the waste will reach the stack, and price each option.

  3. Layout and quote

    Fittings are placed by headroom first, then by looks, and you get an itemised written quote.

  4. First fix

    Pipes and wastes are run through the floor void, the fan is ducted out, any pump or electric shower supply goes in and the walls are boarded.

  5. Tank, tile and fit off

    Wet areas are tanked and tiled, fittings and eaves furniture go in, and the shower is tested at the pressure it will really run at.

Who is it right for?

  • Loft conversions that have a bedroom but no bathroom yet
  • Existing loft shower rooms with a weak shower or a slow-draining waste
  • Houses where a loft bedroom needs its own en-suite
  • Homes with a combi or unvented system, where mains pressure reaches the loft without a pump

What should you watch out for?

  • Never let anyone connect a shower pump directly to the mains supply; pumps are for gravity systems with a cold tank only
  • A cold tank in the same loft gives almost no pressure to a loft shower without a pump
  • Check the headroom where you actually stand, not the height in the middle of the room
  • A macerator can only be used where the house has another WC on gravity drainage

What rules apply to a loft bathroom?

A bathroom inside an existing loft room does not usually need planning permission, but forming one is normally building-regulations work because of the new drainage, extract ventilation and electrics. A macerator or pumped WC is acceptable only where the home also has a WC on gravity drainage. Under the water fittings rules, a shower pump must never be connected directly to the mains supply.

England

In England, new drainage and a new connection to the soil stack fall under Part H, a new bathroom needs extract of 15 litres per second intermittent or 8 litres per second continuous under Approved Document F, and new circuits are notifiable under Part P. If the work includes an unvented hot-water cylinder, it must be fitted by a G3-qualified installer.

Wales

Wales applies its own Part P, with a wider notifiable list than England, and its own Part F with similar extract rates. Part H covers the new drainage route down from the loft.

Scotland

In Scotland, forming a new bathroom in the loft or altering the drainage may need a building warrant. The Technical Handbook uses 15 litres per second extract for a bathroom, and water fittings are covered by the Scottish Water Byelaws 2014.

Northern Ireland

In Northern Ireland, building control covers the new drainage, any structural work to the floor and the ventilation, which is set out in Technical Booklet K. Wiring should be designed, tested and certified to BS 7671.

FAQ

Loft bathrooms: your questions answered

How much does a loft bathroom cost?

A loft bathroom typically costs £6,500 to £13,000 supplied and fitted, including VAT. Refitting an existing loft shower room is usually £5,500 to £8,500; a walk-in shower with fitted eaves furniture and a pump or macerator £8,000 to £13,000; and forming a new loft bathroom in an existing loft room, with a new drainage route and water supply, £10,000 to £18,000.

Do I need a pump for a loft shower?

You need a pump if your hot water comes from a cylinder fed by a cold tank, because the tank usually sits at or below the height of a loft shower and gives almost no pressure. A combi boiler or unvented cylinder supplies mains pressure, so no pump is needed, though the flow can drop when other taps run. Shower pumps must only be used on gravity systems, never connected to the mains.

How much headroom do you need for a loft shower?

Plan for around 2 m of clear height over the whole shower area, and enough standing height in front of the basin and WC. A bath can sit lower under the slope as long as you can stand up where you get in and out. We mark the usable height at each position on the survey drawing.

Can you put a toilet in a loft?

Yes, if the waste can fall to the soil stack or a macerator can be used. Gravity drainage is the first choice; a macerator is only allowed where the home already has a WC on gravity drainage, which in most houses means the main bathroom.

Is a bath too heavy for a loft floor?

A standard acrylic bath is usually fine on a loft floor built for a conversion, but a filled bath with someone in it is heavy, and stone-resin or cast-iron baths are much heavier still. We check the joist size, span and direction at the survey, and a heavy bath may need a structural check and strengthening first.

Electric shower or pumped shower in a loft?

An electric shower heats cold mains water as it flows, so it works in a loft whatever your hot-water system, but its flow is lower than a good pumped or mains-pressure mixer and it needs its own electrical circuit. A pumped mixer gives a stronger shower on a gravity system. See choosing a shower for the full comparison.

How do you ventilate a loft bathroom?

A loft bathroom fan is usually ducted through the roof to a tile or slate vent, or out through a gable wall. The duct should be insulated where it crosses a cold space, so condensation does not run back into the fan. A roof window helps with daylight and airing but does not replace the fan.

How long does a loft bathroom take to fit?

Six to twelve working days. Refitting an existing loft shower room sits at the shorter end; forming a new one, with the drainage run down through the house and a new water supply, sits at the longer end.

Ready for a bathroom that fits properly?

Book a free home survey. You get a measured layout and an itemised written quote before any work starts.