What does a bathroom extractor fan cost in North Yorkshire?
Our guide range in North Yorkshire is £230–£550 including VAT. Prices in North Yorkshire run at about 7% below the UK guide, based on Yorkshire and the Humber labour rates.
Extractor fan
- Wired to regulations
Inline fan
- Quiet fan in the loft void
Continuous extract
- Boost on humidity
Guide prices for North Yorkshire including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in North Yorkshire?
Supplies across most of North Yorkshire are moderately hard. Scale is a minor issue next to condensation, which is what a properly sized extractor fan is for. Hardness varies street by street, so check the figure for your postcode with your water supplier. In York flats, a new vent through an outside wall may need freeholder consent, so we raise it at the survey.
What the job includes
- A backdraught shutter and external grille, so cold air does not blow back in
- Core-drilling through the wall, or ducting through the loft to a roof or soffit vent
- Run-on timer, humidistat or light-linked switching set up to suit how the room is used
- Making good around the fan and checking that it extracts properly at the grille
- A check of the room, any existing fan or vent, and the shortest route to the outside
- A fan chosen to meet the bathroom extract rate: 15 l/s intermittent or 8 l/s continuous
Decisions to make first
Noise
Compare the stated noise level in decibels. Inline fans and low-speed continuous fans are much quieter in the room than budget axial fans.
Replacement air
A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.
Intermittent or continuous
An intermittent fan runs during and after use. A continuous fan runs quietly all the time at a low rate and boosts when humidity rises.
Timer or humidistat
A timer keeps the fan running after the light goes off. A humidistat starts it whenever moisture rises, which suits rooms where people forget.
Rules that apply in England
A bathroom needs extract ventilation when it is newly formed, and on a refit an existing fan should not be replaced with a less effective one. The fan and its wiring must meet BS 7671 for the zone it sits in, on a circuit with 30 mA RCD protection. In a flat, the lease often requires freeholder consent for a new extract vent, and in a listed building a new opening through an external wall can need listed building consent.
In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.