- Postcode districts
- TF1, TF5
- Nearby
- Telford, Shrewsbury and Stafford
- Guide price
- £450–£3,400
- Typical time on site
- half a day to 3 days
- Water
- Moderately hard across most of Shropshire
- Survey
- Free, at your home
What does a new shower cost in Wellington?
For Wellington, our guide range for a new shower is £450 to £3,400 including VAT. The figure depends on the size of the room, whether anything moves, and the products you pick.
Shower swap
- Test and handover
New shower over bath
- Thermostatic bar shower and riser
New shower with enclosure
- Pipework and waste
Guide prices for Wellington including VAT. Your itemised written quote after the free survey is the price that counts.
Working in Wellington
We work right across Wellington — TF1 and TF5 — and in neighbouring Telford and Shrewsbury.
Being a smaller town does not change how we work in Wellington: free survey, written quote, one team. If your Wellington bath has no shower over it, a thermostatic bar shower, screen and tiling can usually be added in a day or two. If you want a shower in your Wellington home that works when the boiler is off, an electric shower is worth considering, as long as the consumer unit can take the circuit.
Supplies across most of Shropshire are moderately hard. A quick wipe of the glass and an easy-clean coating are worth having on a new shower in Wellington. Hardness varies street by street, so check the figure for your postcode with your water supplier.
What the job includes
- A bath screen, tray or enclosure where the shower is new
- New pipework and isolation valves, plus a pump only where the system is gravity-fed from a cold tank
- For an electric shower, a check of the consumer unit and whether a new dedicated circuit is needed
- A check of your hot-water system, water pressure and flow rate
Decisions to make first
Power shower
A mixer with a built-in pump, for tank-fed systems only. It lifts a weak gravity shower but must never be connected to the mains.
Thermostatic mixer
Blends hot and cold from your system and holds the temperature steady when someone runs a tap. The usual choice with a combi or an unvented cylinder.
Rules that apply in England
In England, an electric shower usually needs its own dedicated circuit, often 40 to 45 amps for an 8.5 to 10.5 kW unit, and a new circuit is notifiable under Part P. The Part G limit of 48 °C applies to a new bath in a new dwelling or one created by change of use, not to a shower, but a thermostatic valve gives similar protection. An unvented cylinder fitted to improve the shower must be installed by a G3-qualified installer.