What does bathroom underfloor heating cost in Lincolnshire?
Our guide range in Lincolnshire is £650–£2,400 including VAT. Prices in Lincolnshire run at about 4% below the UK guide, based on East Midlands labour rates.
Electric mat
- Thermostat and RCD-protected supply
Electric, larger room
- Whole floor coverage
Wet system
- Manifold or single-zone kit
Guide prices for Lincolnshire including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Lincolnshire?
Water across much of Lincolnshire is hard. Hard water leaves white marks on dark grout and gloss tiles, so matt finishes and stain-resistant grout are the practical choice. Hardness varies street by street, so check the figure for your postcode with your water supplier. Where a Lincoln home already has a heat pump, or the heating is being altered, a wet underfloor system is worth comparing with electric.
What the job includes
- A check of the floor construction, the room's heat loss and where the thermostat and supply will go
- Bringing the system up to temperature gradually once the adhesive and grout have cured
- Insulation boards over the subfloor, so heat goes up into the tiles rather than down into the joists or screed
- The electric mat or cable laid to the open floor, kept clear of where the WC, bath and fixed furniture will sit
- A floor sensor set between the heating runs and wired back to the thermostat
- A dial, programmable or smart thermostat, with the supply RCD protected, tested and certified by a qualified electrician
Decisions to make first
Insulation board thickness
Thicker boards warm up faster and lose less heat downwards, but raise the floor; the right choice depends on the door threshold and the next room.
Electric or wet
Electric is cheaper to install and quick to lay in one room. Wet costs more upfront but is usually cheaper to run where it is fed by a gas boiler or heat pump.
Mat or loose cable
Mats are quickest on square, open floors. Loose cable is easier to route around awkward shapes, pipe boxing and a curved shower area.
Floor heating and towel rail
Underfloor heating warms the room; a towel rail dries towels. Many bathrooms have both, and a dual-fuel rail keeps working in summer when the boiler is off.
Rules that apply in England
Electric underfloor heating in a bathroom must be on a circuit with 30 mA RCD protection under BS 7671, and the thermostat is positioned to suit the bathroom zones. There is no separate approval for the heating itself, but it should have its own thermostat and timer so it only runs when needed, and the electrical work must meet BS 7671 — in England and Wales it is notifiable as bathroom electrical work. Any work on a gas boiler for a wet system must be done by a Gas Safe registered engineer.
In England, a new circuit for underfloor heating is notifiable under Part P, and so is connecting it to an existing circuit in a room with a bath or shower. The electrician either self-certifies through a competent person scheme or the work is notified to building control.

