What does a bathroom extractor fan cost in Berkshire?
Our guide range in Berkshire is £280–£650 including VAT. Prices in Berkshire run at about 12% above the UK guide, based on South East England labour rates.
Extractor fan
- Fan with timer or humidistat
Inline fan
- Ducting to a roof or soffit vent
Continuous extract
- Good for windowless rooms
Guide prices for Berkshire including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Berkshire?
Supplies across most of Berkshire are hard. Steam carries that scale onto mirrors and glass, so a fan that clears the room quickly helps on both counts. Hardness varies street by street, so check the figure for your postcode with your water supplier. In Reading flats, a new vent through an outside wall may need freeholder consent, so we raise it at the survey.
What the job includes
- Core-drilling through the wall, or ducting through the loft to a roof or soffit vent
- Run-on timer, humidistat or light-linked switching set up to suit how the room is used
- Rigid or semi-rigid ducting kept short and straight, and insulated where it crosses a cold loft
- A backdraught shutter and external grille, so cold air does not blow back in
- Wiring by a qualified electrician, with an isolator outside the room and RCD protection
- A check of the room, any existing fan or vent, and the shortest route to the outside
Decisions to make first
Replacement air
A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.
Wall or ceiling
A wall fan on an outside wall is the simplest. A ceiling fan over the shower takes steam away at source but needs ducting through the loft.
Intermittent or continuous
An intermittent fan runs during and after use. A continuous fan runs quietly all the time at a low rate and boosts when humidity rises.
Timer or humidistat
A timer keeps the fan running after the light goes off. A humidistat starts it whenever moisture rises, which suits rooms where people forget.
Rules that apply in England
A bathroom needs extract ventilation when it is newly formed, and on a refit an existing fan should not be replaced with a less effective one. The fan and its wiring must meet BS 7671 for the zone it sits in, on a circuit with 30 mA RCD protection. In a flat, the lease often requires freeholder consent for a new extract vent, and in a listed building a new opening through an external wall can need listed building consent.
In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.