Free home survey & written quote · Fitted bathrooms across England, Wales, Scotland & Northern Ireland0800 088 6341
Fitted Bathrooms
England · South East England

Extractor fans & ventilation in Surrey

We cover extractor fans & ventilation across Surrey, from Woking to Guildford. Every job starts with a free home survey and an itemised written quote.

£280–£650 inc VAThalf a day26 towns listed
Bathroom extractor fan fitted in the ceiling

What does a bathroom extractor fan cost in Surrey?

Our guide range in Surrey is £280–£650 including VAT. Prices in Surrey run at about 12% above the UK guide, based on South East England labour rates.

Inline fan

£450–£800
  • Ducting to a roof or soffit vent

Continuous extract

£500–£1,000
  • Good for windowless rooms

Guide prices for Surrey including VAT. Your itemised written quote after the free survey is the price that counts.

Which towns do we cover in Surrey?

Most of Surrey has hard water. Steam carries that scale onto mirrors and glass, so a fan that clears the room quickly helps on both counts. Hardness varies street by street, so check the figure for your postcode with your water supplier. Fans fitted in Woking bathrooms are wired by a qualified electrician, with RCD protection and an isolator outside the room.

What the job includes

  • A check of the room, any existing fan or vent, and the shortest route to the outside
  • Wiring by a qualified electrician, with an isolator outside the room and RCD protection
  • Run-on timer, humidistat or light-linked switching set up to suit how the room is used
  • A fan chosen to meet the bathroom extract rate: 15 l/s intermittent or 8 l/s continuous
  • Core-drilling through the wall, or ducting through the loft to a roof or soffit vent
  • Rigid or semi-rigid ducting kept short and straight, and insulated where it crosses a cold loft

Decisions to make first

Wall or ceiling

A wall fan on an outside wall is the simplest. A ceiling fan over the shower takes steam away at source but needs ducting through the loft.

Intermittent or continuous

An intermittent fan runs during and after use. A continuous fan runs quietly all the time at a low rate and boosts when humidity rises.

Axial, centrifugal or inline

Axial fans suit short, straight runs; centrifugal fans cope better with longer ducts; inline fans sit in the loft and are the quietest in the room.

Replacement air

A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.

Rules that apply in England

A bathroom needs extract ventilation when it is newly formed, and on a refit an existing fan should not be replaced with a less effective one. The fan and its wiring must meet BS 7671 for the zone it sits in, on a circuit with 30 mA RCD protection. In a flat, the lease often requires freeholder consent for a new extract vent, and in a listed building a new opening through an external wall can need listed building consent.

In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.

Extractor fans & ventilation in Surrey: questions

How much does a bathroom extractor fan cost in Surrey?

A bathroom extractor fan in Surrey typically costs £280–£650 including VAT, based on South East England prices. The free survey and itemised written quote give you the exact figure for your home.

Which towns in Surrey do you cover?

We cover the whole of Surrey, including Woking, Guildford, Esher, Redhill, Staines, Banstead, Leatherhead and Ewell. If your town is not listed, we still cover it — get in touch with your postcode.

How long does a bathroom extractor fan take?

Most jobs take half a day on site once the products have arrived. We confirm a start date and a day-by-day plan when you approve the quote.

Is the water hard in Surrey?

Most of Surrey has hard water. Steam carries that scale onto mirrors and glass, so a fan that clears the room quickly helps on both counts. Hardness varies street by street, so check the figure for your postcode with your water supplier.

What extraction rate does a bathroom fan need?

In England, Approved Document F asks for 15 litres per second from an intermittent bathroom fan, or 8 litres per second from a continuous one. Scotland's Technical Handbook also uses 15 l/s for a bathroom, Wales has similar rates in its own Part F, and Northern Ireland sets its rates in Technical Booklet K. Choose a fan that reaches the rate through your actual duct run, not just in open air. Our extractor fan rules guide explains more.

Extractor fans & ventilation in Surrey

Book a free home survey anywhere in Surrey. You get a measured layout and an itemised written price.