What does a shower room cost in Rutland?
Our guide range in Rutland is £4,300–£8,600 including VAT. Prices in Rutland run at about 4% below the UK guide, based on East Midlands labour rates.
Essential
- Basin and close-coupled WC
Signature
- Porcelain tiles throughout
Bespoke
- Tiled level-access floor
Guide prices for Rutland including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Rutland?
Most of Rutland has hard water. If your supply in Oakham is the same, limescale on shower glass and heads is a real issue: easy-clean glass, rub-clean nozzles and a squeegee make a big difference. Hardness varies street by street, so check the figure for your postcode with your water supplier. If your second bathroom in Oakham is too narrow for a bath, a long walk-in tray can often fit along the same wall.
What the job includes
- Removal of the old bath and suite, waste removal, testing and handover
- Tanking to the shower area, then wall and floor tiling
- An enclosure, walk-in panel or frameless screen in toughened safety glass
- Recessed niches or shelving in the shower wall
- Extractor fan, lighting and towel rail wired by a qualified electrician, tested and certified
- A thermostatic shower valve, exposed or concealed, with a fixed head, a handset or both
Decisions to make first
Tray size
A 1200 by 800 mm or 1400 by 900 mm tray with a single panel makes a comfortable walk-in. Go as long as the room allows; length does more than width to keep spray inside.
Storage
With no bath, there is often space for a full-width vanity unit or a tall cupboard for towels.
Valve and heads
A bar valve is simple and easy to service. A concealed valve with a ceiling head looks cleaner but needs good flow to perform.
Tray or level floor
A low-profile stone-resin tray is quicker to fit and costs less. A tiled level floor looks seamless but needs a former, tanking and more floor preparation.
Rules that apply in England
Turning a bathroom into a shower room does not need planning permission. The electrics must meet BS 7671: 30 mA RCD protection on every circuit, at least IPX4 fittings in zone 1 above the tray up to 2.25 m, or IPX5 where water jets are used, and no ordinary sockets within 3 m of zone 1. A shower pump can only be used on a gravity system with a cold tank, never connected directly to the mains.
In England, any change to the wiring in the shower room, or a new circuit for an electric shower, is notifiable under Part P. If you are replacing the fan, keep it at least as effective as the old one; Approved Document F gives 15 litres per second intermittent for a bathroom.

