- Postcode districts
- SS16, SS17
- Nearby
- Basildon, Pitsea and Grays
- Guide price
- £265–£650
- Typical time on site
- half a day
- Water
- Very hard across most of Essex
- Survey
- Free, at your home
What does a bathroom extractor fan cost in Stanford-le-Hope?
Our guide price for a bathroom extractor fan in Stanford-le-Hope is £265–£650 including VAT. We adjust the national guide for East of England, where prices are typically about 6% above the UK average. The figure depends on the size of the room, whether anything moves, and the products you pick.
Extractor fan
- Wired to regulations
Inline fan
- Quiet fan in the loft void
Continuous extract
- Boost on humidity
Guide prices for Stanford-le-Hope including VAT. Your itemised written quote after the free survey is the price that counts.
Working in Stanford-le-Hope
As well as Stanford-le-Hope itself (SS16 and SS17), we survey in Basildon, Pitsea and Grays.
Homes in and around Stanford-le-Hope vary, so we look at the floor, the walls and the water system before we price anything. If your Stanford-le-Hope home is listed or in a period terrace, a fan ducted through the loft to a roof vent can avoid a new hole in the front wall, though consent may still apply. In Stanford-le-Hope flats, a new vent through an outside wall may need freeholder consent, so we raise it at the survey.
Water across much of Essex is very hard. Steam carries that scale onto mirrors and glass, so a fan that clears the room quickly helps on both counts. Hardness varies street by street, so check the figure for your postcode with your water supplier.
What the job includes
- A fan chosen to meet the bathroom extract rate: 15 l/s intermittent or 8 l/s continuous
- Making good around the fan and checking that it extracts properly at the grille
- Run-on timer, humidistat or light-linked switching set up to suit how the room is used
- A backdraught shutter and external grille, so cold air does not blow back in
Decisions to make first
Axial, centrifugal or inline
Axial fans suit short, straight runs; centrifugal fans cope better with longer ducts; inline fans sit in the loft and are the quietest in the room.
Replacement air
A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.
Rules that apply in England
In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.