What does a bathroom extractor fan cost in Greater Manchester?
Our guide range in Greater Manchester is £235–£550 including VAT. Prices in Greater Manchester run at about 6% below the UK guide, based on North West England labour rates.
Extractor fan
- Wired to regulations
Inline fan
- Quiet fan in the loft void
Continuous extract
- Boost on humidity
Guide prices for Greater Manchester including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Greater Manchester?
- Manchester
- Oldham
- Wigan
- Bolton
- Stockport
- Salford
- Rochdale
- Sale
- Bury
- Altrincham
- Middleton
- Ashton-under-Lyne
- Leigh
- Stretford
- Urmston
- Chadderton
- Eccles
- Tyldesley
- Hyde
- Walkden
- Prestwich
- Radcliffe
- Cheadle Hulme
- Heywood
- Denton
- Stalybridge
- Ashton in Makerfield
- Westhoughton
- Farnworth
- Saddleworth
- Hindley
- Droylsden
- Whitefield
- Swinton
- Royton
- Atherton
- Old Trafford
- Dukinfield
- Failsworth
- Hazel Grove
- Irlam
- Horwich
- Bramhall
- Ramsbottom
- Bredbury
Supplies across most of Greater Manchester are soft. Even so, condensation is the bigger problem in any bathroom, and a properly sized extractor is what deals with it. Hardness varies street by street, so check the figure for your postcode with your water supplier. If your Manchester bathroom has black mould on the ceiling or silicone, the fan and its duct are the first things we check.
What the job includes
- A backdraught shutter and external grille, so cold air does not blow back in
- Core-drilling through the wall, or ducting through the loft to a roof or soffit vent
- Run-on timer, humidistat or light-linked switching set up to suit how the room is used
- Rigid or semi-rigid ducting kept short and straight, and insulated where it crosses a cold loft
- A check of the room, any existing fan or vent, and the shortest route to the outside
- Wiring by a qualified electrician, with an isolator outside the room and RCD protection
Decisions to make first
Replacement air
A fan needs air to replace what it removes, so leave a gap of around 10 mm under the door or fit a door grille. A sealed room starves the fan.
Wall or ceiling
A wall fan on an outside wall is the simplest. A ceiling fan over the shower takes steam away at source but needs ducting through the loft.
Axial, centrifugal or inline
Axial fans suit short, straight runs; centrifugal fans cope better with longer ducts; inline fans sit in the loft and are the quietest in the room.
Timer or humidistat
A timer keeps the fan running after the light goes off. A humidistat starts it whenever moisture rises, which suits rooms where people forget.
Rules that apply in England
A bathroom needs extract ventilation when it is newly formed, and on a refit an existing fan should not be replaced with a less effective one. The fan and its wiring must meet BS 7671 for the zone it sits in, on a circuit with 30 mA RCD protection. In a flat, the lease often requires freeholder consent for a new extract vent, and in a listed building a new opening through an external wall can need listed building consent.
In England, Approved Document F sets bathroom extract at 15 l/s for an intermittent fan or 8 l/s for continuous extract. Wiring a new fan alters a circuit in a room with a bath or shower, so it is notifiable under Part P.