What does a new shower cost in Edinburgh?
Our guide range in Edinburgh is £450–£3,400 including VAT. Prices in Edinburgh run at about 4% below the UK guide, based on Scotland labour rates.
Shower swap
- Like-for-like mixer or electric shower
New shower over bath
- Bath screen
New shower with enclosure
- Tiling to the enclosure
Guide prices for Edinburgh including VAT. Your itemised written quote after the free survey is the price that counts.
Which towns do we cover in Edinburgh?
Water across much of Edinburgh is soft. If that holds for your street in Queensferry, limescale on shower glass and heads builds up slowly and a squeegee after use is usually enough. Hardness varies street by street, so check the figure for your postcode with your water supplier. If you want a shower in your Queensferry home that works when the boiler is off, an electric shower is worth considering, as long as the consumer unit can take the circuit.
What the job includes
- New pipework and isolation valves, plus a pump only where the system is gravity-fed from a cold tank
- Tiling or re-tiling around the shower, with tanking behind new tiles in the wet area
- Removal of the old shower, a full-flow test and a handover on isolating and descaling it
- A bath screen, tray or enclosure where the shower is new
- Electrical connection by a qualified electrician, tested and certified
- Supply and fitting of the shower valve or unit, riser rail, handset or fixed head
Decisions to make first
Power shower
A mixer with a built-in pump, for tank-fed systems only. It lifts a weak gravity shower but must never be connected to the mains.
Thermostatic mixer
Blends hot and cold from your system and holds the temperature steady when someone runs a tap. The usual choice with a combi or an unvented cylinder.
Exposed or concealed
An exposed bar valve fixes onto the tiles and is easy to service. A concealed valve sits in the wall for a cleaner look but needs careful setting-out and a plan for access.
Head and handset
A handset on a riser rail is versatile and easy for rinsing; a fixed overhead head feels generous but needs strong flow behind it.
Rules that apply in Scotland
The water fittings regulations in each nation do not allow a pump to be connected directly to the mains supply; shower pumps are for gravity systems with a cold tank only. The shower must also be protected against water flowing back into the supply. Electrics must meet BS 7671, with 30 mA RCD protection and at least IPX4 fittings in zone 1, or IPX5 where water jets are used.
In Scotland there is no Part P, but a new shower circuit must still be designed, installed and certified to BS 7671. Water fittings, including pumps and backflow protection, are covered by the Scottish Water Byelaws 2014.