- Postcode districts
- DA5, DA6, DA14, DA15, DA16
- Nearby
- Dartford, Swanley and Barking
- Guide price
- £550–£4,400
- Typical time on site
- half a day to 3 days
- Water
- Very hard across most of Greater London
- Survey
- Free, at your home
What does a new shower cost in Bexley?
For Bexley, our guide range for a new shower is £550 to £4,400 including VAT. Prices in London run at about 25% above the national guide, mainly because of labour rates. The figure depends on the size of the room, whether anything moves, and the products you pick.
Shower swap
- Like-for-like mixer or electric shower
New shower over bath
- Bath screen
New shower with enclosure
- Tiling to the enclosure
Guide prices for Bexley including VAT. Your itemised written quote after the free survey is the price that counts.
Working in Bexley
As well as Bexley itself (DA5, DA6, DA14 and 2 more postcode districts), we survey in Dartford, Swanley and Barking.
In Bexley, many bathrooms are in flats or converted houses, so we check lease consents, access and the floor below before we price. For Bexley homes with a cold tank in the loft, we check the system before fitting anything, because a pump is only allowed on a gravity supply. If the shower in your Bexley home swings between hot and cold, a thermostatic valve is usually the fix.
Supplies across most of Greater London are very hard. If your supply in Bexley is the same, limescale on shower glass and heads is a real issue: easy-clean glass, rub-clean nozzles and a squeegee make a big difference. Hardness varies street by street, so check the figure for your postcode with your water supplier.
What the job includes
- A check of your hot-water system, water pressure and flow rate
- For an electric shower, a check of the consumer unit and whether a new dedicated circuit is needed
- Supply and fitting of the shower valve or unit, riser rail, handset or fixed head
- Removal of the old shower, a full-flow test and a handover on isolating and descaling it
Decisions to make first
Exposed or concealed
An exposed bar valve fixes onto the tiles and is easy to service. A concealed valve sits in the wall for a cleaner look but needs careful setting-out and a plan for access.
Power shower
A mixer with a built-in pump, for tank-fed systems only. It lifts a weak gravity shower but must never be connected to the mains.
Rules that apply in England
In England, an electric shower usually needs its own dedicated circuit, often 40 to 45 amps for an 8.5 to 10.5 kW unit, and a new circuit is notifiable under Part P. The Part G limit of 48 °C applies to a new bath in a new dwelling or one created by change of use, not to a shower, but a thermostatic valve gives similar protection. An unvented cylinder fitted to improve the shower must be installed by a G3-qualified installer.